Medium voltage circuit breakers & protection

Specialist knowledge of medium-voltage circuit breakers, protection relays and the functional relationship between switching, protection and tripping.

Switching and protection belong together

A protection relay may respond correctly, but ultimately the functional trip chain must operate successfully. Conversely, a mechanically well-functioning circuit breaker does not automatically mean the protection and control are operating correctly.

Protection relay
Trip circuit
Shunt trip
Circuit breaker
Mechanical operation

A technical assessment can therefore not always stop at a single component. Depending on the installation and configuration, a deviation may lie in the:

Protection
Settings
Output contact
Trip circuit
Coil
Control
Mechanism
Circuit breaker

Medium-voltage circuit breakers

Withdrawable medium-voltage circuit breaker in a switchgear installation

Assessment tailored to your situation

Depending on your situation, this may involve vacuum (VCB), SF₆, oil or another design. Relevant assessment areas may include:

  • Visual and mechanical condition
  • Mechanical operation
  • Opening and closing times
  • Pole synchronism where relevant
  • Contact resistance
  • Condition of the interruption system where relevant
  • Coils, controls and operating mechanism
  • Functional operation

Protection and trip chain

We explicitly treat the protection relay as part of the functional chain. Focus areas include, where applicable:

  • Protection relay testing
  • Secondary current injection
  • Checking relevant settings
  • Assessing relay response
  • Output contacts
  • Functional trip chain

Technical history in the Asset Passport

Measurement results, relevant protection settings, findings, reports, photos, and technical documentation can be brought together in the Asset Passport for the respective installation or asset. This keeps visible which condition was determined, what work was carried out, and what information is available for future maintenance, further investigation, retrofit, or replacement.

Request medium-voltage assessment?

Provide us with as many details as possible for a targeted response.

  • Manufacturer and circuit breaker type
  • Protection relay type (if present)
  • Nameplate data
  • Photos and available schematics
  • Relevant settings
  • Description of fault, maintenance, or test requirement